Viltrus MB-10 MBus to Modbus converter
The Viltrus MB-10 acts as a concentrator on the MBus bus and the data from it is available over the RS-485 bus via the Modbus RTU protocol. Wiring As described, connect the MBus bus to the individual terminals, RS-485 to the concentrator (be careful, the polarity of the wires matters), and a 12-36 V DC power supply. Settings Once all the meters on the MBus bus have been set up and connected to the converter, connect to the converter via USB cable (with Mini connector) and run the MB_250 …
-
M-Count 2C převodník pulsů na M-Bus
The M-Count 2C from Cynox is a two-input S0 pulse converter (typically the output of electric meters and galvanic isolators) to MBus. Commissioning Remove the insulating foil on the battery Set the power jumper to EXT - connecting the pins in the middle and closer to the battery Connect the module according to the following diagram a. MBus bus to the terminals marked M-BUS b. 24V power supply to terminals V+I (+) and GND (-)
-
IMP-O-TENT W-MBus 169 MHz Transmitter
Before starting, it is necessary to screw the antenna onto the connector on the module’s wire pin. Transmitting without an antenna could permanently damage the transmitter (1) Use the power jumper to connect the pins marked ON (2) Connect the USB cable supplied by the manufacturer to a free USB port on the computer and identify the marking of the corresponding COM port. Click on Start, type Device Manager in the Search Programs and Files field and open.
-
Requirements for installation work on Enectiva projects – automatic data collection from gauges
It is important to follow the instructions bellow while working on Enectiva installation projects. General If you are replacing a gauge or installing new one, then you have to fill the exchange protocol (which includes description of old and new gauge condition). It is necessary to write down the serial numbers of old and new gauges and M-bus module serial number too. After installation of any gauge or after mounting a digital output to the gauge or after installation of central unit you will …
-
Design of energy measurement systems in industrial sites
This manual serves as a standard for project architects and designers of energy measurement systems, who are using technologies working with M-Bus protocol. The aim of this standard is to provide a clear and transparent assignment of energy consumptions to technological units (heating, cooling, ventilation, production, lightning,…) or to economical units (renter, economic center,…). Another aim of this standard is to prepare a whole system of measurements for automatic data collection …
-
W-MBus 169 MHz Softlink transmitter setup
The wireless softlink module can be set up in two ways - via cable or via infrared interface. Before the actual setting, the switches located on the board next to the battery must be switched to the ON position Connecting the module to a computer using a cable Connect the cable supplied by the manufacturer with the USB-CMOS converter to a free USB port on the computer. Then, in the Device Manager window, find the assigned COM port number, e.