You will use a passive splitter if you want to divide one input pulse signal into two identical ones. We use it mostly in case we need to share the meter data with a third party. Typically, these are gas and waterworks, where one distributor from the hub will be used by the distributor and the other by us in Enectiva.
The converter can then be connected to an M-Bus converter (eg Pad Pulse) or converted to wireless eg via WMBUS 169, Wmbus 868 etc. Sigfox, LoRa etc. can also be connected to the pulse output.
Procedure
- To adjust, first remove the caps from the hub and then remove the entire top cover.
- The connection is very simple. Just pull the pulse output from the meter to the left of the meter and pull the split signal from the terminals to the right for other purposes.
- After connecting all inputs and outputs, close, cover and place the hub as needed.
ATTENTION !!!
It is necessary to keep the polarity of all inputs and outputs according to the terminal block label. Classic is White Wire Plus.